MICROPORT NEURO (02172): UFO Spark Self-Expanding Intrasaccular Aneurysm Embolization Device Enters NMPA Innovation Green Channel

date
08:07 25/11/2026
avatar
GMT Eight
MicroPort NeuroTech (02172) announced that the UFO Spark Self-Expanding Intrasaccular Aneurysm Embolization Device developed by the Group has passed the National Medical Products Administration (NMPA)'s Special Review Application for Innovative Medical Devices and entered the Special Review Procedure (Green Channel). This selection marks the Group's 9th product included in the NMPA's Special Review for Innovative Medical Devices.
MICROPORT NEURO (02172) announced that the UFO Spark Self-Expanding Intrasaccular Aneurysm Embolization Device developed by the Group has passed the special review application for the NMPA Innovative Medical Management device and entered the special review procedure (green channel). This selection marks the Group's 9th product included in the NMPA Innovative Medical Management device special review. The UFO Spark Self-Expanding Intrasaccular Aneurysm Embolization Device approved for the green channel this time is an Innovative Medical Management device designed specifically for the treatment of intracranial aneurysms. Relying on an advanced intrasaccular hemodynamic regulation concept and a unique configuration design, it enables physicians to achieve precise deployment along the central axis of the aneurysm during minimally invasive interventional release in minimally invasive interventional procedures. Its design aims to reduce multiple intraoperative adjustments, lower procedure-related risks, improve aneurysm neck coverage, and help protect surrounding branch vessels; at the same time, the dual-layer configuration design combines excellent wall apposition compliance and stable support capability, which can efficiently reshape the intrasaccular hemodynamic environment, promote intrasaccular thrombosis and aneurysm neck endothelialization, ensure patency of the parent artery and adjacent branch vessels, and reduce interference with normal cerebral blood supply. Intracranial bifurcation aneurysms are a special subtype of intracranial aneurysms, mostly located at vascular bifurcations, subjected to high hemodynamic impact, and complex in morphology. Common locations include the internal carotid artery terminus, middle cerebral artery bifurcation, anterior communicating artery, basilar artery apex, fetal posterior cerebral artery, origin of a large posterior inferior cerebellar artery, and some pericallosal and callosomarginal arteries, accounting for approximately 26.0%50.9% of all intracranial aneurysms (IA). Intracranial bifurcation aneurysms have a relatively high rupture risk and are one of the important causes of spontaneous subarachnoid hemorrhage, accounting for approximately 60% of all ruptured intracranial aneurysms (RIA). The treatment of intracranial bifurcation aneurysms requires complete occlusion of the aneurysm while maintaining patency of the parent artery and branch vessels, and therefore still faces certain challenges. The emergence of the UFO Spark Self-Expanding Intrasaccular Aneurysm Embolization Device provides an innovative treatment option for patients with complex intracranial aneurysms such as wide-necked and bifurcation aneurysms. The Group is committed to the development and promotion of Innovative Medical Management solutions and currently has 29 neurointerventional products, covering major diseases such as aneurysms, stenosis, and thrombectomy. Nine products of the Group have been included in the NMPA Innovative Medical Management device green channel. The other eight are the Tubridge Flow-Diverting Stent, Bridge Vertebral Artery Rapamycin Target-Eluting Stent, Tigertriever Intracranial Thrombectomy Stent, Rebridge Intracranial Artery Stent, StraitPass Single-Use Hematoma Aspiration Device, NuFairy Absorbable Coil, Artemis Dream Self-Expanding Intracranial Rapamycin-Eluting Stent System, and NuWismen Liquid Embolic Agent, of which 3 have already been launched and promoted. In addition, one product, the APOLLO Dream Intracranial Artery Rapamycin Target-Eluting Stent System, has received Breakthrough Device Designation from the U.S. Food and Drug Administration.