VENUS MEDTECH-B (02500): First Global Release of 6-Month Clinical Follow-up Data from the TARGET Study of the CARDIOVALVE TR System

date
17:03 24/11/2026
avatar
GMT Eight
VENUS MEDTECH-B (02500) announced that recently, the 6-month full-cohort clinical follow-up data from the TARGET study of its independently developed innovative medical device, the Cardiovalve transcatheter tricuspid valve replacement system (Cardiovalve TR System), were released globally for the first time at PCR London Valves 2026.
VENUS MEDTECH-B (02500) announced that recently, the 6-month full-cohort clinical follow-up data from the TARGET study of its self-developed Innovative Medical Management device Cardiovalve transcatheter tricuspid valve replacement system (Cardiovalve TR System) were released globally for the first time at PCR London Valves 2026. The TARGET study is a prospective, single-arm, multicenter clinical study primarily designed to evaluate the safety and clinical performance of the Cardiovalve TR System. The study enrolled a total of 157 patients from nearly 30 cardiovascular centers across Germany, Spain, Italy, the United Kingdom, and Canada. Study results showed that the Cardiovalve TR System met both the primary performance endpoint and the primary safety endpoint. At 6 months post-procedure, the proportion of patients with no/trace tricuspid regurgitation reached 76.7% (120 evaluable patients in the implant group), and this was sustained through 3 years post-procedure (76.9%, 26 evaluable patients). Patients' functional status, exercise capacity, and quality of life showed improvement early after implantation and were maintained throughout the follow-up period: at 1 year post-procedure, the 6-minute walk distance improved by an average of 42 meters, and the Kansas City Cardiomyopathy Questionnaire (KCCQ) score improved by an average of 20 points; at 3 years post-procedure, regarding New York Heart Association (NYHA) functional class improvement, the proportion of patients in NYHA class I/II increased from 39.9% at baseline to 80%. The right heart system showed positive reverse remodeling, with the inferior vena cava diameter, right ventricular end-diastolic mid-segment diameter, and basal segment diameter decreasing by an average of 25%, 22%, and 11%, respectively, at 3 years post-procedure. In terms of safety, at 30 days post-procedure, the all-cause mortality rate was 5.7%, the heart failure rehospitalization rate was 1.9%, and the incidence of major access site and vascular complications requiring surgical intervention was 5.1%. Compared with the first-generation delivery system, the enhanced delivery system reduced the incidence of major bleeding events from 21% to 5.0% and the incidence of major vascular complications from 8.8% to 3.0%. The Cardiovalve TR System is a self-developed transcatheter tricuspid valve replacement product. Compared with similar products, the transfemoral vein approach of the Cardiovalve TR System significantly improves treatment safety. The large annulus design of up to 55mm can cover approximately 95% of the patient population; the unique short stent frame design effectively reduces the risk of ventricular outflow tract obstruction; the operation process is simple, requiring only three stepspositioning, anchoring, and releasedemonstrating good safety and reproducibility. The 6-month full-cohort results and up to 3-year follow-up data from the TARGET study further validate the sustained clinical benefits and long-term durability of the Cardiovalve TR System in high-risk patients with severe tricuspid regurgitation. Leveraging the self-developed transfemoral vein approach design, the safety improvements brought by the enhanced delivery system, and the Group's established advantages in R&D, manufacturing, and sales in the global structural heart disease field, the Group will continue to actively advance the CE certification registration process and clinical promotion of this product to benefit patients worldwide.